  data sheet keysight technologies u2701a/U2702A usb modular oscilloscope
features C 100 mhz and 200 mhz bandwidths C up to 1 gsa/s maximum sample rate C 32 mpts of waveform memory C compact and portable size C advanced triggering, including edge, pulse width and tv C four math functions, including ffts standard C dual-play function C standalone and modular capability C compatibility with high-speed usb 2.0 and usbtmc-usb488 standards the keysight technologies, inc. u2701a and U2702A usb modular oscilloscopes combine a set of essential features that are ideal for analyzing designs in an affordable way. the u2701a and U2702A come in two bandwidths: 100 mhz and 200 mhz respectively. these devices are uniquely designed to accommodate your need for flexibility with the dual-play function. this function allows you to use the oscilloscope as a standalone instrument, or to scale up the test system in a cardcage with additional scopes or with other keysight usb modular product offerings, providing a complete solution for system development. the u2701a/U2702A usb modular oscilloscopes give you the debugging power you need. each usb modular oscilloscope comes with standard features such as advanced triggering, automatic measurements, math functions including ftts and much more. introduction
figure 1. the dual-play capability allows the u2701a/U2702A usb modular oscilloscope to be used as a standalone unit or as part of test system in a cardcage. ease of use the u2701a/U2702A usb modular oscilloscopes are equipped with high-speed usb 2.0 interface for easy setup and plug-and-play. this ease of use makes the oscilloscopes ideal for the education, design validation and manufacturing industries. why do you need deep memory and a high sampling rate? to view results over a longer period a deep memory lets you to store more samples, allowing you to view the signal and results over a longer period of time. a longer capture time gives you better vis - ibility into the cause-effect relationships in your design. this allows you to capture start-up events in a single acquisition, and can significantly simplify your root-cause debugging. with the u2701a/U2702A usb modular oscilloscopes, you no longer need to stitch together multiple acquisitions or set precise triggering condition, allowing you to spend less time finding events, and more time analyzing them. to view signals in greater detail all oscilloscopes have a banner maximum sample rate, but many can only sustain these rates at a few time base set - tings. the u2701a/U2702A usb modular oscilloscopes have a deep memory depth that is able to store a large amount of data, letting you zoom in on signals for more detail. to achieve higher accuracy by offering a sampling rate more than twice the acquired signal bandwidth, the u2701a/U2702A can prevent aliasing. by capturing more samples, you can obtain higher test and analysis result accuracy. 3 | keysight | u2701a/U2702A usb modular oscilloscope - data sheet
features you need the u2701a and U2702A include the following standard features that you need to perform your tasks efficiently: hi-speed usb interface the u2701a and U2702A connect to the computer through hi-speed usb 2.0 connectivity. autoscale autoscale lets you display any active signals, automatically setting the vertical, horizontal, and trigger controls for the best signal display within the shortest time. advanced triggering edge, pulse width, and tv are the trigger - ing modes included to help you isolate the signals you want to see. large memory with memory depth up to 32 mpts, you can capture even more data. larger memory allows you to capture data over a longer time frame. fast fourier transfer (fft) and waveform math the u2701a and U2702A usb modular oscilloscopes offer analysis functions such as addition, subtraction, multiplication, division, and fast fourier transform (fft). fft allows you to manipulate the wave - form using five types of windows such as hanning, hamming, blackman-harris, flattop, and rectangular. figure 2. the u2701a and U2702A connect to the computer or laptop with a usb cable, enabling fast data transfer. high sampling rate a sampling rate up to 500 msa/s/ch allows you to view and analyze the signal in greater detail. when two channels are interleaved, the sampling rate can rise up to 1 gsa/s. this fast-sampling capability allows you to perform intermittent detections easily. pulse triggering pulse triggering allows you to trigger on pulse events. portability the u2701a and u2701as compact size makes them portable, and they can be easily carried to and around your work field. three-year warranty every u2701a and U2702A comes with a three year warranty. 4 | keysight | u2701a/U2702A usb modular oscilloscope - data sheet
rear view top view 117. 0 0 mm 180.00 mm 15.00 mm product characteristics and general specifcations remote interface C hi-speed usb 2.0 C usbtmc 488.2 class device 1 power consumption C +12 vdc, 2 a C installation category iii operating environment C operating temperature from 0 c to +50 c C operating humidity at 20% to 85% rh (non-condensing) C altitude up to 2000 meters C pollution degree 2 C for indoor use only storage compliance C storage temperature from C20 c to 70 c C storage humidity at 5% to 90% rh (non-condensing) safety compliance certifed with: C iec 61010-1:2001/en 61010-1:2001 (2nd edition) C usa: ul61010-1: 2004 C canada: csa c22.2 no.61010-1:2004 emc compliance C iec 61326-1:2002/en 61326-1:1998+a2:2001+a3:2003 C canada: ices-001:2004 C australia/new zealand: as/nzs cispr 11:2004 shock and vibration tested to iec/en 60068-2 io connector bnc connector dimension (w d h) module dimension: C 117.00 mm 180.00 mm 41.00 mm (with bumpers) C 105.00 mm 175.00 mm 25.00 mm (without bumpers) weight C 534 g (with bumpers) C 482 g (without bumpers) warranty three years for u2701a/U2702A three months for standard shipped accessories product outlook and dimensions front view standard shipped accessories C 12 v, 2 a ac/dc power adapter C power cord C usb standard a to mini-b interface cable C 2 x 10:1 passive probe 150 mhz 1.2m, n2862a (only applicable for u2701a) C 2 x 10:1 passive probe 300 mhz 1.2m, n2863a (only applicable for U2702A) C l-mount kit (used with modular product chassis) C keysight automation-ready cd-rom (contains the keysight io libraries suite) C keysight usb modular products quick start guide C keysight usb modular products reference cd-rom C keysight usb modular products quick reference card C certificate of calibration 41.00 mm optional accessories C bnc cable, u2921a-100 C usb secure cable, u2921a-101 C 1:1 passive probe 20 mhz, 1.5 m, 10070c (order no.: u2701a-200) C 10:1 passive probe 150 mhz 1.2m, n2862a (only applicable for u2701a) C 10:1 passive probe 300 mhz 1.2m, n2863a (only applicable for U2702A) 1. compatible with microsoft windows operating systems only. requires a direct usb connection to the pc so the appropriate driver can be installed in the usb modular instrument. 5 | keysight | u2701a/U2702A usb modular oscilloscope - data sheet
performance specifcations 1 vertical system: oscilloscope channels andwidth ( d) 7a: d to mhz 7a: d to mhz scope channel triggering trigger sensitiity < 10 mv/div: greater of 1 div or 5mv; 10 mv/div: 0.6 div performance characteristics 2 acquisition: oscilloscope channels real time sample rate C 2 channels interleaved C each channel 1 gsa/s 500 msa/s standard memory depth C 2 channels interleaved C each channel normal single-shot 32 mpts 64 mpts 16 mpts 32 mpts vertical system: oscilloscope channels scope channels 7a7a: h and h simultaneous acquisition a coupled u2701a: 3.5 hz to 100 mhz U2702A: 3.5 hz to 200 mhz calculated rise time (= 0.35/bandwidth) u2701a: 3.5 ns U2702A: 1.75 ns 2 mv/div to 5 v/div (1 m) cat i 30 vrms, 42 vpk 4 div 4 div 1 m?: 16 pf 25 mhz 10:1 passive probe 150 mhz 1.2 m 10:1 passive probe 300 mhz 1.2 m 200 mv/div: 0.1 div 2.0 mv 0.5% offset value; > 200 mv/div: 0.1 div 2.0 mv 1.5% offset value dc vertical gain accuracy 4.0% of full scale 1. all specifications are warranted. specifications are valid after a 30-minute warm-up and within 100 oc of last calibration temperature. 2. all characteristics are typical performance values and are not warranted. characteristics are valid after a 30-minute warm-up period and within 10 oc of last calibration temperature. 3. under standalone use, you are only allowed to measure up to cat i 30 vrms. for high-voltage measurement up to cat i 300 vrms, you must install the l- mount kit on the u2701a/U2702A before plugging it into the product chassis. ensure that the l-mount kit installed on your modular oscilloscope is screwed to the product chassis to ensure proper chassis grounding. note that you are required to use the provided 10:1 probes (n2862a/n2863a) for high-voltage measurements to avoid damaging your instrument. 6 | keysight | u2701a/U2702A usb modular oscilloscope - data sheet
performance characteristics 1 (continued) vertical system: oscilloscope channels (continued) singlecursor accuracy {dc vertical gain accuracy + dc vertical offset accuracy + 0.2% full scale (~1/2 lsb)} accuracy = {4.0% (80 mv) + 0.1(10 mv) + 2.0 mv + 0.5% (5 mv) + 0.2% (80 mv)} = 6.385 mv {dc vertical gain accuracy + 0.4% full scale (~1 lsb)} accuracy = {4.0% (80 mv) + 0.4% (80 mv)} = 3.52 mv horizontal range nsdi to sdi time ase accuracy ppm delay range pre-trigger: C100 % post-trigger: +100 % trigger system sources h h ext (not applicale for tv trigger) modes ormal single auto trigger hold off time 60 ns C edge triggers on a rising or falling edge, alternating, or either edge of any source C pulse width triggers on a pulse width greater than, equal to, or less than a specifed time limit, with time limits ranging from 16 ns to 10 s minimum upper limit: 16 ns C tv triggers on one of three standard television waveforms: ntsc, pal, secam tv trigger sensitivity: 0.6 division of sync signal. modes supported include field 1, field 2, all felds, or any line within a feld oscilloscope channel triggering range (internal) 4 div from center screen lf reject (~ 35 khz) hf reject (~ 35 khz) external (ext) triggering nput impedance 1 mw: 16 pf cat i 30 vrms, 42 vpk range dc coupling: trigger level 1.25 v and 2.5 v ext trigger pulse width > 2.5 ns 1. all characteristics are typical performance values and are not warranted. characteristics are valid after a 30-minute warm-up period and within 10 oc of last calibration temperature. 7 | keysight | u2701a/U2702A usb modular oscilloscope - data sheet
performance characteristics 1 (continued) external (ext) triggering (continued) trigger leel sensitiity for 1.25 v range setting: dc to 100 mhz: 100 v > 100 mhz: 200 v for 2.5 v range setting: dc to 100 mhz: 250 v > 100 mhz: 500 v display nterpolation sin(x)x display types dots and ectors persistence off, infnite measurement features automatic measurements measurements are continuously updated. cursors track last selected measurement. C modes: manual C type: time, voltage and frequency (fft) C measurements: dt, dv, frequency, peak scan (fft), dpeak math functions add, substract, multiply, fft, divide fft points points (for ns and aoe) source of fft source channels or window hanning hamming lacmanharris rectangular flattop noise foor 1. all specifications are warranted. specifications are valid after a 30-minute warm-up and within 100 oc of last calibration temperature. 8 | keysight | u2701a/U2702A usb modular oscilloscope - data sheet
keysight measurement manager the keysight measurement man - ager (kmm) is an application data viewer software that comes with the standard purchase of the u2700a series usb modular instruments. this software is designed to help you perform quick device configuration, data logging and data acquisition using the products. supported features found in the u2701a/ U2702A usb modular oscilloscope: C averaging C command logger to allow the capture of configuration commands that can be easily converted to snippets of vee, vb, c++ and c# code C self-test C self-calibration C option to save the current instrument configuration to a file C data logging and export feature to csv, html and text only format files that can be printed C trigger settings between modules in the instrument chassis with star trigger and master/slave trigger keysight measurement manager prerequisites prior to installing the keysight measurement manager software, ensure that your pc meets the following minimum system requirements for installation and operation. requirement windows xp operating systems windows vista operating systems windows 7 operating systems operating system windows xp serice pac (or later) windows vista (it) serice pac and windows 7 (it and 64-bit) 3, 4 600 mhz or 1 ghz 32-bit (x86) 3 ghz 32-bit (x86) 256 mb minimum 1.5 gb minimum 1.5 gb minimum 1.5 gb minimum super vga (800 600) 256 colors or 6 explorer 5.01 or greater 1. supported windows xp editions home or professional 2. supported windows vista (32-bit) editions home basic, home premium, business, or ultimate 3. supported windows 7 (32-bit and 64-bit) editions home basic, home premium, professional, enterprise, or ultimate 4. keysight measurement manger for windows 7 64-bit support is a 32-bit application running on a wow64 (windows-on-windows 64-bit) emulator. 5. super vga graphics is supported for windows vista and windows 7. 6. the type of media provided with the product determines whether a cd-rom drive or dvd-rom drive is required. software requirements keysight io libraries suite 15.1 and above keysight t&m toolkit runtime version 2.12 keysight t&m toolkit redistributable package 2.1 patch microsoft .net framework version 2.02 1. available on the keysight automation-ready cd-rom 2. bundled with keysight measurement manager software application installer 9 | keysight | u2701a/U2702A usb modular oscilloscope - data sheet
other products in the keysight usb modular test instruments family u2722a/u2723a usb modular source measure unit features: C three-channel smu with four-quadrant source/measure operation high measurement sensitivity of 100 pa with 16-bit resolution for all voltage and current ranges C 0.1% basic accuracy C embedded test scripts (for u2723a) f or more information: http://www.keysight.com/find/u2722a http://www.keysight.com/find/u2723a u2741a usb modular digital multimeter (dmm) features: C fast reading speed (up to 100 sa/s) C wide range of basic measurement functions, including frequency and temperature measurements for more information: http://www.keysight.com/find/u2741a u2751a usb modular switch matrix features: C minimal cross-talk of -30 db at 45 mhz wide bandwidth C high bandwidth at 45 mhz without terminal block C capability to test up to four devices-under-test (duts) C works with other keysight instruments for multi-point testing for more information: http://www.keysight.com/find/u2751a u2761a usb modular function/arbitrary waveform generator features: C direct digital synthesis (dds) waveform generator C pulse generator that can generate pulse signal as stimulus C easy customization with arbitrary waveform editor C internal modulation capability simplifies test setup for more information: http://www.keysight.com/find/u2761a u2781a usb modular product chassis features: C expansion of channels for each modular product C multiple instrument synchronization C internal and external 10 mhz reference clock C high-speed usb 2.0 C ssi/star trigger bus synchronization between external trigger source and modules for more information: http://www.keysight.com/find/u2781a 10 | keysight | u2701a/U2702A usb modular oscilloscope - data sheet
ordering information model description 7a s modular oscilloscope ( mhz) 7a s modular oscilloscope ( mhz) optional accessories model description n2862a 10:1 pas sive probe, 150 mhz, 1.2 m (for u2701a) n2863a 10:1 passive probe, 300 mhz, 1.2 m (for U2702A) 10070c 1:1 passive probe, 20 mhz, 1.5 m bnc cable, 1.2 m 11 | keysight | u2701a/U2702A usb modular oscilloscope - data sheet
12 | keysight | u2701a/U2702A usb modular oscilloscope - data sheet this information is subject to change without notice. ? keysight technologies, 2012 - 2016 published in usa, january 21, 2016 5990-9537en www.keysight.com www.keysight.com/find/usbscope for more information on keysight technologies products, applications or services, please contact your local keysight office. the complete list is available at: www.keysight.com/find/contactus americas canada (877) 894 4414 brazil 55 11 3351 7010 mexico 001 800 254 2440 united states (800) 829 4444 asia pacifc australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 11 2626 japan 0120 (421) 345 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 other ap countries (65) 6375 8100 europe & middle east austria 0800 001122 belgium 0800 58580 finland 0800 523252 france 0805 980333 germany 0800 6270999 ireland 1800 832700 israel 1 809 343051 italy 800 599100 luxembourg +32 800 58580 netherlands 0800 0233200 russia 8800 5009286 spain 800 000154 sweden 0200 882255 switzerland 0800 805353 opt. 1 (de) opt. 2 (fr) opt. 3 (it) united kingdom 0800 0260637 for other unlisted countries: www.keysight.com/find/contactus (bp-01-01-16) www.keysight.com/go/quality keysight technologies, inc. dekra certified iso 9001:2008 quality management system mykeysight www.keysight.com/find/mykeysight a personalized view into the information most relevant to you. three-year warranty www.keysight.com/find/threeyearwarranty keysights committed to superior product quality and lower total cost of ownership. keysight is the only test and measurement company with a three-year warranty standard on all instruments, worldwide. and, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. keysight assurance plans www.keysight.com/find/assuranceplans up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. keysight infoline www.keysight.com/find/service keysights insight to best in class information management. free access to your keysight equipment company reports and e-library. keysight channel partners www.keysight.com/find/channelpartners get the best of both worlds: keysights measurement expertise and product breadth, combined with channel partner convenience. from hewlett-packard through agilent to keysight for more than 75 years, weve been helping you unlock measurement insights. our unique combination of hardware, software and people can help you reach your next breakthrough. unlocking measurement insights since 1939. 1939 the future